Sign In | Join Free | My uabig.com
China Beijing GFUVE Instrument Transformer Manufacturer Co.,Ltd. logo
Beijing GFUVE Instrument Transformer Manufacturer Co.,Ltd.
Beijing GFUVE Instrument Transformer Manufacturer Co.,Ltd. an exclusive current transformer, split core current transformer, current clamp & voltage transformer manufacturer.
Active Member

8 Years

Home > CT PT Analyzer >

High Precision Portable CT PT Analyzer 0.02% / 0.05% Ratio Error With Printer

Beijing GFUVE Instrument Transformer Manufacturer Co.,Ltd.
Contact Now

High Precision Portable CT PT Analyzer 0.02% / 0.05% Ratio Error With Printer

  • 1
  • 2
  • 3

Brand Name : GFUVE

Model Number : GF1061

Certification : CE, ISO9001

Place of Origin : BEIJING CHINA

MOQ : 1SET

Price : 25000-35000USD/SET

Payment Terms : L/C, D/A, D/P, T/T, Western Union, MoneyGram

Supply Ability : 200SETS/MONTH

Delivery Time : 2-3weeks

Packaging Details : Standard Export Box

Name : CT PT analyzer

Application : current transformer and potential transformer test

Theory : DC variable-frequency methods

LCD : 7inch TFT touch color LCD

Phase error : 1min or 3min

Ratio error : 0.02% or 0.05%

CT raito : 1-50000

PT ratio : 1-10000

Usage : Measurement CT and Protection CT

Contact Now

0.02 Class High Precision Portable CT PT Analyzer with Printer

GF1061 portable CT PT analyzer is mainly used for field or lab testing, it can finish the measurements (M) and protection (P) class CT, PT and TYP class CT. Adopt 7 inch touch TFT LCD, self-equipped mini type printer supporting field printing; supporting to use USB flash disk to dump data. The CT PT Analyzer is the most complete and easy-to-use testing system for protection and metering CTs according to IEEE and IEC standards.

The CT Analyzer automatically determines all relevant current transformer values and compares the results with the selected standard. The device evaluates the current transformer as per the IEC or IEEE standard within seconds with the push of a button. it can test current transformer and potential transformer ratio error and phase rerror, Magnetization curve etc.
It facilitates fast and economical on-site testing and calibration of metering and protection current transformers. Manufacturers of current transformers, high voltage transformers and switchgear also use the CT Analyzer for tests during development and production.

MAIN FUNCTIONS

I. Current Transformer (CT) II. Voltage Transformer (PT)
1. Magnetization curve 1. Excitation characteristic test
2. Transformation ratio test 2. Transformation ratio test
3. Polarity 3. Polarity
4. 5% and 10% error curve 4. Ratio error, phase error
5. Accuracy limiting factor (ALF) 5. Degauss
6. Degauss 6. Calculation of knee point value
7. Ratio error, phase error 7. Actual secondary load test (burden test)
8. Automatic calculation of excitation knee
point value
8. Resistance test
9. Actual secondary load test (burden test)
10. Resistance test 
11. Secondary time constant (Ts)
12. Remanence coefficient (Kr)
13. Transient dimensioning factor (Ktd)
14. Peak instantaneous error (Er)
15. Magnetizing inductance (LU)
16. Instruments security factor(FS)
17. Composite error

PARAMETERS

Electrical parameters
Accuracy 0.05%
Power supply AC 220V±10% or AC 120V±10%, 50/60Hz or Battery
Output voltage 0-100Vrms
Output current 0-5Arms (20A peak-value)
Output power 0-400 VA (1500 VApeak)
Automatic frequency variation range 0.1-60Hz
Equivalent excitation voltage ≤5000V
Accuracy ≤0.5%
Secondary winding DC resistance measurement Range 0.1-1000Ω
Accuracy ≤0.05%
Secondary actual load measurement Range 5VA-1000VA
Accuracy ≤0.5%±0.1VA
CT/PT phase error measurement Accuracy ±1min (typical) / 3 min (guaranteed)
Resolution 0.1min
CT ratio error measurement Range 1-50000
Accuracy ≤0.05%
PT ratio error measurement Range 1-10000
Accuracy ≤0.05%
Standards 
Reference standards GB1207-2006, GB1208-2006, GB16847-1997
IEC60044-1, IEC60044-6, IEC61869-2, ANSI/IEEE C57.13
Safety standards GB 4793.1-2007
EMC EMC standard 89/336/EEC
FCC Subpart B of Part 15 Class A
IEC 1000-4-2 /3 /4 /6
Mechanical parameters 
Overall dimension (L x W x H) (mm) 280 x 250 x 160
Weight (kg) ≤4
Environmental conditions 
Relative humidity Relative humidity 5%-95% not condensing
Operating temperature -10°C to +50°C
Storage temperature -20°C to +70°C
Altitude ≤1000m

Photo

High Precision Portable CT PT Analyzer 0.02% / 0.05% Ratio Error With Printer


Product Tags:

transformer test instruments

      

circuit breaker analyzer

      
Wholesale High Precision Portable CT PT Analyzer 0.02% / 0.05% Ratio Error With Printer from china suppliers

High Precision Portable CT PT Analyzer 0.02% / 0.05% Ratio Error With Printer Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Beijing GFUVE Instrument Transformer Manufacturer Co.,Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)